Standard

Standard

There are 20, 10, and 5 L options.

 

“TERMION STANDARD” is a universal ultra-thin thermal insulation coating from the full series of ultra-thin thermal insulators. It is used on all types of surfaces with operating temperatures ranging from –60 °C to +200 °C.

It is used for effective thermal insulation of pipelines, metal roofing materials, tanks and cisterns, cooling plants, other metal structures, and industrial equipment. The Termion Standard is also used on surfaces made of vapor-permeable materials (glass, plastic, and others).

Termion Standard contains 80% “3M” glass-ceramic microgranules (France) and 20% silicone microgranules, an acrylic base, and other rheological additives.

Core technology: the viscous phase, which consists of a high-quality imported binder (dispersion), contains microspheres filled with evacuated air from glass-ceramics with a low thermal conductivity coefficient and silicone, ultraviolet filters, and rheological additives.

When applied to any surface, the coating polymerizes, covering the surface with a film of vacuum-adsorbed ceramic and silicone microspheres, forming a thermal barrier.

Method of application:

  1. Before applying the coating, mix thoroughly by hand or with a mechanical mixer (speed up to 200 revolutions per minute).
  2. Requirements for the surface to which thermal insulation is applied: dry, firm, and clean (free of grease, dirt, and dust)
  3. Applying Thermion Standard to painted surfaces is not recommended
  4. Use a roller, brush, or airless sprayer for application.
  5. The ambient temperature during application should be between +5 °C and +40 °C.
Base color
White
Solvent
Demineralized water
Appearance of the coating
Matte, smooth, homogeneous
Mass fraction of non-volatile substances
Not less than 70%
Density g/cm³
0,55
Coverage power, g/m2
176
Calculated thermal conductivity W/m°C
0,0012
Heat dissipation W/m°С
3,9
Thermal resistance m²*C\W (per 1 mm)
1,0
Vapor permeability coefficient Mg/m h PA
0,012
Adhesion
1 point
Flammability rating (except for the NF modification)
G1
Adhesion of the coating by the force of separation:
1. coating to brick MPa
2,00
2. Concrete coatings MPa
1,28
3. Coatings for steel MPa
1,2
Storage (in well-sealed containers)
12 months
Actual consumption (single-layer coating) l / m²
0,8~1,0
Drying time at a temperature of (20 ± 2) °C
Half an hour
Dry from dust
Half an hour
Complete drying to the third degree
40 min
Interlayer drying
24 hours
Complete polymerization
48 hours

Price on request